Cube-bundel2.png

Cube bundle

bundel.png

CUBE-Bundle

500 kWh, in the size of a fridge

Flyer
  • Hydrogen type
    • Green hydrogen (from electrolysis)
    • Type 4 cillinders
  • Services
    • Transport
    • Connecting & disconnecting
    • Back-up storage
  • e-Capacity per load
    • >500 kWh (450 bar)
    • >420 kWh (350 bar)
    • >360 kWh (300 bar)
  • Working pressure (15 °C)
    • 450 bar (maximum)
    • 350 bar
    • 300 bar
    • 20 bar (minimum)
  • Maximum capacity (15 °C)
    • 35,1 kg (450 bar)
    • 28.9 kg (350 bar)
    • 25,5 kg (300 bar)
  • Usable capacity (15 °C)
    • 32,9 kg (450 bar)
    • 27,6 kg (350 bar)
    • 24 kg (300 bar)
  • Demensions
    • 1,20 x 1,20 x 2,55 meter
  • Weight
    • <2.000 kg
  • Certifications
    • ADR / TPED 2010/35/EU / ISO 10961
  • Site Requirements
    • Distance to buildings (< 4m height): > 5 meters
    • Distance to buildings (> 4m height): > 10 meters
    • Distance to flammable objects (e.g., batteries): > 5 meters
    • Surface: Paved ground or steel road plates
    • Usage: Outdoor use only (not covered/indoors)
    • Access: Clear access route for hydrogen exchange/swap
    • ATEX Zone: 1.7 meters around the hydrogen unit
    • Additional Information: Please refer to the Watermeln documentation for environmental authorities (Omgevingsdiensten).